Megger MIT 1525

Insulation Tester 15 KV Megger’s range of MIT insulation resistance testers are targeted at original equipment manufacturers and industrial companies. The top of the new range MIT1525 performs insulation resistance tests up to 15 kV with a 30 TΩ maximum resistance and an accuracy of ±5 % from 1 MΩ up to 3 TΩ.
Megger DLRO 200

Ducter Test Micro ohm MeterMegger DLRO200 measures resistances between 0.1 μΩ and 1 Ω, at high currents. This versatile instrument can provide test currents from 10 A up to 200 A, subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results.
Megger OTS 60PB

Portable Transformer Oil Test Set (BDV Test) Megger’s automatic portable oil test sets perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids. Moulded test vessels give repeatable results in the field and laboratory with lock in precision electrode gap setting adjustment wheels. The transparent, shielded lid is a key feature enabling users […]
Hipot AC 50 KV

High voltage Inc -PFT 503 C Only single piece, shielded cable output AC hipot rated 50 kVac @ 3 kVA. Half the size and weight ofothers and easier to use.
Megger 120 KV DC

Lightest weight available in air-insulated high- voltage model Advanced performance with long-term reliability provided by filtered half-wave rectification Designed for maximum operator safety High Voltage DC Dielectric Test Sets provide the most dependable, portable DC highvoltage sources for checking the quality of electrical power cables, motors, switchgear, insulators, transformers and capacitors.
Hipotronics 860PL-B 60kV

The 800PL Series DC hipot testers are an economical solution to DC field testing of cables, terminations, motors, generators and other electrical apparatus. This series comes in a single unit design that ranges from 5kV to 60 kV.
Schneider Square DS33595

Full-function Test Kit (FFTK), Masterpact or Powerpact circuit breakers. Verify circuit breaker family by referring to circuit breaker label or instruction bulletin when configuring circuit breaker parameters for secondary injection testing.
Omicron CIBANO 500

The following 5 standard tests can be carried out on all circuit breakers using CIBANO 500: Static contact resistance test (micro-ohm measurement), Timing tests, Coil and motor current analysis, Minimum pick-up test, Undervoltage condition test.
Omicron CT Analyzer

The following values can be determined using the CT Analyzer: Accuracy of the ratio and phase angle, taking into consideration the nominal burden and connectedburden, CT excitation and saturation, Burden impedance, Winding resistance, Saturated and non-saturated inductance, CT polarity.
Omicron CP TD1

Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laboratory precision.